HARDWARE
Hydraulic Connectors
Fitting Swagelock Connectors
Info |
---|
This guide explains how to fit and connect the Swagelock-type tube fittings supplied with all GDS Instruments pressure vessels. These instructions are valid for tube fittings 1-inch (25mm) and smaller. All larger fittings will be supplied assembled and sealed by GDS Instruments |
Swagelock-type connector diagram
Note |
---|
Safety Precautions
|
Installation of Swagelock-type hydraulic tube fittings
Fully insert the tube into the fitting and against the connector body,
Rotate the backing nut finger-tight,
Mark the nut at the 6 o’clock position,
For 8mm and 6mm tube fittings: while holding the connector body steady, tighten the nut one and one-quarter turns to the 9 o’clock position,
For 1/8'' and 4mm tube fittings: while holding the connector body steady, tighten the nut three-quarters turn to the 3 o’clock position.